Turbine jets are loud. At full power, close to the model, they often reach roughly 110 to 125 dB(A). EDF jets are much quieter, at roughly 80 to 95 dB(A) near the model. Pulse jets are louder than turbines. Hearing protection is essential at any running turbine, including for the pilot.
What makes a turbine loud
A turbine makes two main sounds: a high-pitched whine from the compressor and turbine, and a roar from the exhaust. The whine is high-frequency, which hearing protection blocks well. The roar is broader. Both get louder with throttle and as you get closer to the engine.
Typical noise levels
| Source | Approximate level | Notes |
|---|---|---|
| EDF jet, near the model | About 80 to 95 dB(A) | Varies with fan and power |
| Turbine at full power, close range | About 110 to 125 dB(A) | Varies with engine and distance |
| Turbine ground run at a few metres | About 95 to 110 dB(A) | Starts and ground runs are where helpers get the most exposure |
| Pulse jet | Often reported above 130 dB | Restricted or banned at many flying sites |
These are approximate figures. If your site has noise limits, measure your own setup before you rely on these numbers.
Distance matters
In open air, sound drops by about 6 dB each time you double your distance from the source. Stepping back a few metres makes a real difference. Levels at the pilot’s station during flight are generally lower than at the start point.
Exposure limits
The US National Institute for Occupational Safety and Health (NIOSH) uses 85 dB(A) over 8 hours as a reference limit. Each 3 dB increase halves the safe time. By that yardstick:
- At 100 dB(A), the reference time is around 15 minutes.
- At 110 dB(A), it’s around 1.5 minutes.
These are workplace guidelines, but they’re a useful yardstick for starts and ground runs. At 110 dB(A), safe exposure is measured in minutes.
Choosing hearing protection
- Foam earplugs are commonly rated around NRR 29 to 33.
- Earmuffs are commonly rated around NRR 20 to 31.
- Labels overstate real protection. A common method, used by OSHA, is to subtract 7 from the NRR and then halve the result. For a plug rated NRR 30, that’s (30 − 7) × 0.5 = 11.5 dB.
Turbine whine is mostly high-frequency, and plugs and muffs block that well. Wear hearing protection for every start, ground run and pit session, not only when you’re at the controls.
Who needs protection
- The pilot, especially during the start and ground run.
- Helpers, who often stand closest during starts.
- Pit crew and anyone in the pit area.
- Spectators, especially children, who should be kept back from a running turbine.
Club noise limits
Clubs and national associations often set noise limits measured at a set distance. Check your club’s rules and the national guidance before you fly, and check local ordinances if you fly near homes. A quieter EDF jet may suit a site with tight limits.
Next steps
For how to run a start safely, see how to start an RC jet turbine safely. For a first-jet plan, see RC turbine jets for beginners. For the bigger picture, see RC jet engines: turbines, EDFs and how to get started.